HIGH ACCURACY- Measuring range 196/328ft
(60m/100m) measuring accuracy up to +/- 2.0mm, single measurement time
is 0.5s, laser type is 500~690nm with grade II, <1MW. Operation 1.Switch-on Short press to switch on the equipment,and laser point is opened at the same
time.indication as shown as figure A. Laser point is automatically shut
down if no any operation after 30seconds.Or short press to close the laser point, indication as shown as figure B. Short press again to open laser point, indication as shown as figure A . 2.Change Measurement Reference Default measuring reference is the bottom of meter,indication as shown as figure A . Long press to change the measuring reference to the top of meter,indication as shown as figure C. 3. Unit Conversion Factory default that unit is m, indication as shown as figure A. Long press to switch unit m to Ft, indication as shown as figure D. Long press again to switch the unit Ft to In, indication as shown as figure E. (Note: Long press to switch the unit of measurement will switch the value at the same time if it has value of measurement.) When the unit of measurement is m², long press to switch the unit to ft²,long press again to switch the unit to In².When the unit of measurement is m³,long-time press to switch the unit to ft³,long press again to switch the unit to In³. 4.Change Measurement Mode Default setting of measurement is single measurement mode, indication as shown as figure A. Short press to switch area measurement mode, indication as shown as figure F.Short press again to switch volume measurement mode, indication as shown as figure G . Short press again to switch pythagoras measurement mode to measuring height, indication as shown as figure H. Short press again to switch Height Difference pythagoras measurement mode ,indication as shown as figure I. Short press again to switch Historical Data Review mode,indication as shown as figure J. 5. Switch off The equipment can be switched off at any time by long time press . 6. Historical Data Scroll up Check/Data Clear In Historical Data Review mode ,measuring data indication as shown as figure K. Short press or Short press to the historical reading one by one forward .Bigger number means the newer measuring value, indication as shown as figure L. Short press ,delete measuring data records one by one forward.(Note:The equipment can store the most recent 20 measuring
data. At this time, it will measure data storage records that factory
tested. It not means this equipment has been used.) 7. Single measurement of distance between two points In the single measurement mode, aim the laser onto target Short press . The result willbe displayed immediately as shown as figure M. 8. Continuous measurement of distance between two Points In the state of switch-on, long press to enter the continuous measurement mode, indication as shown as figure O. 9. Area Measurement In the area measurement mode and aim the laser onto target.Short press to measure the two side lengths of the target respectively,area measurement results will be displayed as shown as figure P. 10. Volume Measurement In
the volume measurement mode and aim the laser onto target. Short press
and measure the three side lengths of the target respectively. The
result will be displayed immediately as shown as figure Q. 11. Plus and Minus Functions When the equipment is switched on, indication as shown as figure A . Short press , the current measurement result is added to the previous one and the indication as shown as figure R .Short-time press , the current measurement result is subtracted from the previous one,
as shown in figure S .(Note: The default previous measurement value is
0.000m) When measuring area and volume, short-time press or , the current measurement result is added to or subtracted from the previous one also. 12. Height Measurement(Pythagorean Theorem) In
the Height Measurement (Pythagorean Theorem) mode,the meter is in the
horizontal position and aim the laser onto the bottom of the target .
Short press to measure the right-angle side length of the triangle.Then
keep the reference point of the meter unchanged and aim the laser onto
the top of the target .Short press again to measure the length of the
hypotenuse of a right triangle. The height value of the right triangle
is displayed immediately on the screen as shown as figure T.
13. Mute Mode
When
the equipment is switched on ,the default setting of buzzer is switched
on. The equipment will beep when measuring . Long press , hear “beep”,
the mute mode switch on, the equipment will not beep when measuring .
14.Height Difference Measurement(Pythagorean Theorem)
In
the height difference measurement(Pythagorean Theorem) mode,the meter
is in the horizontal position and aim the laser onto the datum of the
target. Short-time press to measure the right-angle side length of the
triangle.Then keep the reference point of the meter unchanged and aim
the laser onto the bottom of the target . Short-time press again to
measure the second length of the hypotenuse of a right triangle.Then
keep the reference point of the meter unchanged and aim the laser onto
the top of the target .Short-time press again to measure the first
length of the hypotenuse of a right triangle.The height value of the
right triangle is displayed immediately on the screen as shown as figure
U Notes All the pictures used in the manual are only illustrative illustrations, not the actual display of the equipment.